Back to top
  • Send SMS
  • Send Inquiry

DGL-1M DC Ground Fault Locator

DGL-1M DC Ground Fault Locator

Product Details:

  • Product Type Fault Locator
  • Material Outside :- Plastic
  • Measuring Voltage Range 300 Volt (v)
  • Operating Temperature -10 to 55 Celsius (oC)
  • Frequency (MHz) <=12Hz Hertz (HZ)
  • Dimension(L*W*H) 134*190*55 Millimeter (mm)
  • Weight 0.8 Kilograms (kg)
275000 INR/Piece
X

Price And Quantity

  • 01 Piece
  • 275000 INR/Piece

Product Specifications

  • -10 to 55 Celsius (oC)
  • Fault Locator
  • <=12Hz Hertz (HZ)
  • Outside :- Plastic
  • 01 year
  • 300 Volt (v)
  • 0.8 Kilograms (kg)
  • 134*190*55 Millimeter (mm)

Trade Information

  • Cash in Advance (CID)
  • 4-6 Week
  • All India

Product Description

The DGM-1M is a portable light weight instrument used to locate ground fault in DC systems. It consists of a transmitter Unit T-1M and Receiver Unit R-1M. The transmitter is connected to live / non-live floating system up to 300V DC preferably on the DC bus. It then transmits low frequency and low voltage signal in the DC system without affecting the sensitive operation of relays. The transmitted signal is then tracked by receiver to locate the fault feeder and to track it further up to the point of fault. The instrument is fully automatic and detect earth faults / mixing of source at ease.

Application 

Floating DC systems are the back bone of any substation. Mal-operation of DC system / non availability of sound DC system can lead to very big catastrophe in the substation. And hence it is a necessity that the floating DC systems in the substation should be free from any faults. The DC Ground Locator DGL-1M helps substation engineers in locating, tracing, pinpointing DC Ground Faults in any floating DC system up to 300V DC in ONLINE condition. The instrument balance the capacitance of DC system automatically and is fully automatic to detect any faults. The instrument incorporates advanced signal processing to eliminate noise in the DC system and is very sensitive to any ground faults. It also helps in tracking mixing of source in dual Battery system.

Specification - DGL-1M 

 

  • Application: Used Online / Offline In Any Floating Dc System Up To 300 V.
  • Power: Rechargeable li-Ion Batteries Charged By5v Charger
  • Receiver :Rechargeable Site Replaceable Li-Ion Batteries Charged By 9v Charger
  • Signal Voltage:<=15 Vac
  • Short Circuit Current:<5ma
  • Signal Frequency:<=12hz
  • Output Impedance:100 Kohms To Dc System
  • Fault Resistance: Up To400 K 1 MΩ
  • Sensor Probe: High Sense Current Probes68mm,,24mm,Optional 45mm,6mm
  • Control: Fully Automatic
  • Distance: Up To 3 Kilo Meters
  • Capacitive Balancing: Automatic

 

Temperature:

 

  • Storage: -10 To 55⁰ C
  • Operating: -10 To 55⁰ C

 

Dimensions In mm:

 

  • Transmitter 134x190x55
  • Receiver 95x175x40

 

Weight:

 

  • Transmitter ~0.8kg
  • Receiver ~0.2 Kg
Advantage
  • Locates & pinpoint’ s DC Ground fault iv ONLINE & OFFLINE condition.
  • Incorporates automatic capacitive balancing & is fully automatic.
  • Highly immune to noise iv the system.
  • Ultra high sensitive to fault signa.
  • Extremely light weight and user friendly.
  • Truly portable receiver with plug and play battery replacement with simultaneous spare battery recharge capability.
  • Caw pinpoint multiple faulty / mixing with ease.
  • Extremely small voltage and current injection in  order to avoid interference to DC system.

 


TRANSGRID TEST AND MEASUREMENT LLP

* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



TRANSGRID TEST AND MEASUREMENT LLP
211, JSONS FELICIA, 2 A Cross, Aecs Layout, Singasandara,Bengaluru - 560068, Karnataka, India
Phone :+918037303767
Mr. Magesh Jayaraman (Products Specialist)
Mobile :918037303767
Product Showcase
  • Send SMS
  • Send Inquiry